RESTORATION OF CROWN FRACTURES WITH A FIBER POST, POLYETHYLENE FIBER AND COMPOSITE RESIN: a combined restorative technique with two case reports

Autores/as

  • Cagatay Barutcigil
  • Osman Tolga Harorli
  • Mehmet Yildiz

DOI:

https://doi.org/10.7213/aor.v5i1.23266

Palabras clave:

Crown fracture. Fracture treatment. Root canal post. Dental materials.

Resumen

OBJECTIVE: To describe the treatment of two patients who had horizontal crown fractured maxillary incisors a few years after endodontic treatment. METHOD: The 23 and 19-year-old male patients presented to Atatürk University Dentistry Faculty with complex crown fractures. The treatment included a glass fiber reinforced root canal post, a fiber ribbon core and restoration with a universal resin composite. RESULTS AND CONCLUSION: The one-year follow-up examinations showed that the restorations were still in place and successful.

Descargas

Los datos de descargas todavía no están disponibles.

Publicado

2009-11-29

Cómo citar

Barutcigil, C., Harorli, O. T., & Yildiz, M. (2009). RESTORATION OF CROWN FRACTURES WITH A FIBER POST, POLYETHYLENE FIBER AND COMPOSITE RESIN: a combined restorative technique with two case reports. Archives of Oral Research, 5(1). https://doi.org/10.7213/aor.v5i1.23266