Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability

Authors

  • Fabiana Amaral de Carvalho Universidade de Itaúna (UI)
  • Letícia Cristina Carvalho Silva Universidade de Itaúna (UI)
  • Regina Adriana Nogueira Universidade de Itaúna (UI)
  • Stella Maria Cândido Camargos Universidade de Itaúna (UI)
  • Andressa Silva Universidade Federal de Minas Gerais (UFMG)
  • Viviane Santos Borges Universidade de Itaúna (UI)

DOI:

https://doi.org/10.1590/1980-5918.030.S01.AO14

Abstract

Introduction: The sphygmomanometer test is an alternative and inexpensive method for assessment of muscle strength. This instrument was considered valid and reliable to measure the isometric strength in different health conditions, however, in individuals with limb amputations the properties of this instrument for this purpose, have not been investigated. Objective: To investigate the concurrent criterion validity, test-retest and inter-rater reliabilities of the aneroid sphygmomanometer test (AST) without modification, for assessment of the strength of subjects with lower limb amputations.Methods: Twenty-two subjects (57.6 ± 15.2 years) with lower limb amputations were included in this study. Maximum isometric force was assessed with a handheld dynamometer (microFet2®) and the AST. To identify differences between trials, one-way ANOVA was applied. To assess the concurrent criterion validity, test-retest and inter-rater reliabilities of the AST, Pearson’s correlation coefficients of determination and intra-class correlation coefficient (ICC) were calculated. Results: For all muscle groups, no differences were observed between the trials (0.00001 ≤ F ≤ 0.10; 0.90 ≤ p ≤ 0.99). Significant, positive, and high to very high correlations were found between the HHD and the AST measures for the different numbers of trials for all assessed muscles (0.76 ≤ r ≤ 0.93; p ≤ 0.02). Test-retest (0.67 ≤ ICC ≤ 0.97) and inter-rater reliabilities (0.78 ≤ ICC ≤ 0.97) were adequate. The values obtained with the AST were good predictors of those obtained with HHD (0.58 ≤ r2 ≤ 0.85). Conclusion: For individuals with lower limb amputation, the AST showed adequate concurrent criterion validity, test-retest reliability and inter-rater reliability for the assessment of lower limbs muscle strength.

Downloads

Download data is not yet available.

Downloads

Published

2017-11-30

How to Cite

de Carvalho, F. A., Silva, L. C. C., Nogueira, R. A., Camargos, S. M. C., Silva, A., & Borges, V. S. (2017). Sphygmomanometer test to evaluate muscle strength in individuals with lower limb amputation: validity and reliability. Fisioterapia Em Movimento (Physical Therapy in Movement), 30. https://doi.org/10.1590/1980-5918.030.S01.AO14

Issue

Section

Original Article

Most read articles by the same author(s)